Volume 37 Issue 5
Oct.  2023
Turn off MathJax
Article Contents
GAO N, LIU X H. A preliminary study on calibration-free hot-wire anemometry method[J]. Journal of Experiments in Fluid Mechanics, 2023, 37(5): 1-8 doi: 10.11729/syltlx20230004
Citation: GAO N, LIU X H. A preliminary study on calibration-free hot-wire anemometry method[J]. Journal of Experiments in Fluid Mechanics, 2023, 37(5): 1-8 doi: 10.11729/syltlx20230004

A preliminary study on calibration-free hot-wire anemometry method

doi: 10.11729/syltlx20230004
  • Received Date: 2023-01-09
  • Accepted Date: 2023-04-27
  • Rev Recd Date: 2023-03-09
  • Publish Date: 2023-10-30
  • The study aimed to investigate convective heat transfer from a heated circular cylinder with a diameter of 5 microns and a length-to-diameter ratio of approximately 200 or more using experimental methods. A new relationship between the Nusselt number and the Reynolds number was proposed. The results obtained from this study and those reported in the literature were fitted linearly to a curve. This curve served as the basis for proposing a novel hot-wire velocity measurement technique. In this method, velocities are directly calculated from the voltage outputs of the anemometer without requiring calibration. However, validation measurements indicated that there were errors of up to 23% between the measured and actual values. These errors may be due to measurement uncertainties in the probe's length, cold resistance measurement, the resistance of the lead wire, and connectors.
  • loading
  • [1]
    FREYMUTH P. Frequency response and electronic testing for constant-temperature hot-wire anemometers[J]. Journal of Physics E: Scientific Instruments, 1977, 10(7): 705–710. doi: 10.1088/0022-3735/10/7/012
    [2]
    TROPEA C, YARIN A L, FOSS J F. Springer Handbook of Experimental Fluid Mechanics[M]. Berlin: Springer, 2007.
    [3]
    PERRY A E. Hot-wire anemometry[M]. Oxford: Clarendon Press, 1982.
    [4]
    SMITS A J, MUCK K C. Constant temperature hot-wire anemometer practice in supersonic flows[J/OL]. Experiments in Fluids, 1984, 2(1): 33-41[2023-01-09]. http://link.springer.com/10.1007/BF00266316. doi: 10.1007/BF00266316
    [5]
    LEKAKIS I. Calibration and signal interpretation for single and multiple hot-wire/hot-film probes[J]. Measurement Science and Technology, 1996, 7(10): 1313–1333. doi: 10.1088/0957-0233/7/10/004
    [6]
    KING L V. On the convection of heat from small cylinders in a stream of fluid: Determination of the convection constants of small platinum wires, with applications to hot-wire anemometry[J]. Proceedings of the Royal Society A:Mathematical, Physical and Engineering Sciences, 1914, 90(622): 563–570. doi: 10.1098/rspa.1914.0089
    [7]
    MORRISON G L. Errors in heat transfer laws for constant temperature hot wire anemometers[J]. Journal of Physics E: Scientific Instruments, 1976, 9(1): 50–52. doi: 10.1088/0022-3735/9/1/016
    [8]
    GEORGE W K, BEUTHER P D, SHABBIR A. Polynomial calibrations for hot wires in thermally varying flows[J]. Experimental Thermal and Fluid Science, 1989, 2(2): 230–235. doi: 10.1016/0894-1777(89)90038-1
    [9]
    BREMHORST K. Effect of fluid temperature on hot-wire anemometers and an improved method of temperature compensation and linearisation without use of small signal sensitivities[J]. Journal of Physics E: Scientific Instruments, 1985, 18(1): 44–49. doi: 10.1088/0022-3735/18/1/013
    [10]
    BRUUN H H. Hot-wire anemometry: principles and signal analysis[M]. Oxford: Oxford Unversity Press, 1995: 26.
    [11]
    HULTMARK M, SMITS A J. Temperature corrections for constant temperature and constant current hot-wire anemometers[J]. Measurement Science and Technology, 2010, 21(10): 105404. doi: 10.1088/0957-0233/21/10/105404
    [12]
    KAYS W M, CRAWFORD M E. Convective heat and mass transfer[M]. 3rd ed. New York: McGraw-Hill, 1993.
    [13]
    COLLIS D C, WILLIAMS M J. Two-dimensional convection from heated wires at low Reynolds numbers[J]. Journal of Fluid Mechanics, 1959, 6(3): 357. doi: 10.1017/s0022112059000696
    [14]
    KOCH F A, GARTSHORE I S. Temperature effects on hot wire anemometer calibrations[J]. Journal of Physics E: Scientific Instruments, 1972, 5(1): 58–61. doi: 10.1088/0022-3735/5/1/021
    [15]
    LIGRANI P M, BRADSHAW P. Subminiature hot-wire sensors: development and use[J]. Journal of Physics E: Scientific Instruments, 1987, 20(3): 323–332. doi: 10.1088/0022-3735/20/3/019
    [16]
    BRUUN H H. On the temperature dependence of constant temperature hotwire probes with small wire aspect ratio[J]. Journal of Physics E:Scientific Instruments, 1975, 8(11): 942–951. doi: 10.1088/0022-3735/8/11/018
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Figures(8)  / Tables(2)

    Article Metrics

    Article views (225) PDF downloads(86) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return